2 × Phanta Flash Master Mix (Dye Plus)

Cat# P520-02

Size : 5×1ml

Brand : Vazyme

Contact local distributor :


Phone : +1 850 650 7790


2 × Phanta Flash Master Mix (Dye Plus) P520




Product Information

2 × Phanta Flash Master Mix (Dye Plus) is a new generation superior enzyme based on Phanta Flash Super-Fidelity DNA Polymerase. Through directed optimization of Phanta DNA Polymerase,Phanta Flash Super-Fidelity DNA Polymerase has the characteristics of rapid amplification (4 - 5 sec/kb) while maintaining high fidelity and yield. Matched with optimized buffer system, this kit can achieve high amplification specificity. And it has excellent compatibility with crude samples, templates with uracil and GC-rich system (primer/template). This kit contains two types of monoclonal antibodies that inhibit the 5'→3' polymerase activity and 3'→5' exonuclease activity at room temperature, enabling it to perform hot start PCR with great specificity. It contains all required reaction components (Phanta Flash Super-Fidelity DNA Polymerase, dNTP and optimized buffer), except primers and templates, thereby simplifying the operation process and improving the detection throughput and repeatability. This kit contains loading buffer, which can be directly spotted for electrophoresis after the reaction. Amplification will generate blunt-ended products, which are compatible with ClonExpress kits (Vazyme #C112/C113/C115) and TOPO cloning kit (Vazyme #C601).

Product Features

This product is suitable for PCR with various templates such as genomic DNA, cDNA,
plasmid DNA, dU-containing DNA, crude samples, etc.

1. Ultra-fast Amplification
2. High-Fidelity
3. High Specificity

Contents

Components P520-01 P520-02 P520-03
2 × Phanta Flash Master Mix (Dye Plus) 1 ml 5 × 1 ml 15 × 1 ml

Storage

Store at -30 ~ -15℃  for up to 12 months, and transport at ≤0℃.

FAQ

Q1: The amplification efficiency is low and there are no amplified bands in the test group.

A1: (1) Primers

Check whether the synthetic primers have degraded due to improper storage; review primer design and use BLAST to examine primer specificity or redesign primers.

(2) Template

Long-term storage or repeated freeze-thaw cycles will lead to DNA breakage, nicking, or degradation, so the template should be the freshly prepared double-stranded DNA. An excessively high GC content in the template will make it difficult to separate DNA double strands; in this case, add PCR Enhancer (Cat. No. P021) to effectively lower the melting temperature. Crude sample templates may contain inhibitors, so it is recommended to lower the template concentration (use after dilution; if a plant leaf is used, make sure the plant is not rich in polysaccharides or polyphenols, take a fresh, young leaf, and trim it to the size of the end of a yellow pipette tip). If cDNA is used, check the purity and integrity of the RNA used for reverse transcription.

(3) Enzyme

The enzyme used in the reaction has been inactivated. Repeat the experiment with a fresh enzyme or an enzyme from another source.

(4) Amplification system

The reaction system has been prepared incorrectly. Repeat the experiment with the correct system.

(5) Reaction program

Check whether the denaturation temperature is correct and whether the temperature displayed on the PCR system is the same as the actual temperature. If the temperature is too high, the enzyme will be rapidly inactivated in the first few cycles. If the temperature is too low, the template will not be completely denatured. If yeast is used as the template, the pre-denaturation time may be extended to 10 minutes. If the annealing temperature is inappropriate, determine the appropriate annealing temperature by testing a gradient of annealing temperatures. If the target fragment is long, try the touchdown PCR program. Check whether the extension time is sufficient.

 

Q2: The amplified bands are faint.

A2: (1) Primers

Check whether the synthetic primers have degraded.

(2) Template

Check the quality of the template. Long-term storage or repeated freeze-thaw cycles will lead to DNA breakage, nicking, or degradation, so the freshly prepared double-stranded DNA should be used as the template. If the template has been used up, use serial dilutions of the initial amplification product as the templates for subsequent amplification.

(3) Reaction program

Try the touchdown PCR program; increase the extension time and the number of cycles.

 

Q3: Amplification specificity is poor, or there are non-specific products.

A3: (1) Primers

Primer design is not optimal. If primers have bound to non-specific sites in the target sequence or to each other to form dimers, optimize by reducing the primer concentration or redesigning primers if necessary.

(2) Template

If the template is impure or contaminated, prepare a new template.

If the template has degraded, or too much template has been used, examine the integrity and concentration of the template by electrophoresis, and purify the template again if necessary. Consult the Instructions for Use for the template input amount.

(3) Reaction program

The reaction program is not optimal. If there are non-specific miscellaneous bands smaller than the target band, increase the annealing temperature and reduce the number of cycles. If there are non-specific miscellaneous bands larger than the target band, reduce the extension time and the number of cycles.

 

Q4: The bands are diffuse or smeared when amplification products are run on a gel.

A4: (1) Gel

Melt the gel completely during preparation.

(2) Primers

Check whether the primers have degraded.

(3) Template

The template is degraded or excessive. Examine the integrity and concentration of the template by electrophoresis, and prepare a new template if necessary. Consult the Instructions for Use for the template input amount. If the target band is long and the cDNA is used as the template, check the purity and integrity of the RNA used for reverse transcription, and perform reverse transcription again without random primers.

(4) Reaction program

The reaction program is not optimal. If the annealing temperature is inappropriate, determine the appropriate annealing temperature by testing a gradient of annealing temperatures. Try the touchdown PCR program.

 

Q5: There are amplification products in the blank control (NTC) group.

A5: (1) Problematic primer design

The amplified sequence is homologous to the non-target sequence. Thus, non-target sequences are also amplified in PCR.

(2) If the band corresponding to the amplification product has the same size as the target bands, this indicates contamination.

Repeat the experiment with a fresh Mix, water, or primers. Prepare the reaction system on an ultra-clean workbench to minimize aerosol contamination.

(3) To avoid cross-contamination of the target sequence by the genome or large fragments, perform the steps with care to prevent the target sequence from being pipetted into the loading pipette or spilling from centrifuge tubes.

(4) To avoid contamination of the target gene by small airborne nucleic acid fragments, use the nested PCR method to reduce or eliminate contamination.

 

Q6: The high-fidelity polymerase has poor fidelity and introduces mutations.

A6: Mutations in high-fidelity PCR may be analyzed from the following aspects:

(1) There are mutations in the template.

Check whether the template is mutated. If it is a plasmid, submit it for sequencing. If it is cDNA, repeat the test; if the mutation is still present, there may be issues with the cDNA. In this case, it is recommended to prepare new cDNAs after checking the integrity and purity of the RNA.

(2) The mutation may result from prolonged exposure of the template to UV light.

Avoid prolonged UV exposure during gel extraction.

(3) The gene sequence is inconsistent with the NCBI sequence.

Resubmit the DNA for sequencing. If the result remains the same, it means that the sequence may be inconsistent with the one listed on NCBI.

(4) Similar recombinant sequences lead to wrong recombination.

 

Q7: How many templates should be input if the reverse transcription product cDNA is used as the template for high-fidelity PCR?

A7: The cDNA template input amount recommended in the Instructions for Use is 1–5 μl (no more than 1/10 of the total volume of the PCR system). Determine the appropriate input amount by testing different template amounts within this range.

 

Q8: Do dyed PCR products affect restriction digestion?

A8: Tests show that dyed PCR products do not affect restriction digestion.

 

Q9: Do amplification products obtained with high-fidelity polymerases have poly(A) tails? How to add poly(A) tails?

A9: (1) The amplification products obtained with high-fidelity polymerases do not have poly(A) tails. For subsequent cloning, try Vazyme's seamless cloning product C601; for TA cloning, add a poly(A) tail using a universal Taq polymerase:

Poly(A) tailing method: 10 μl system with the Taq polymerase only:

1 μl of 10 × Taq Buffer (containing MgCl2)

0.5 μl of 10 mM dNTPs

0.2 μl of Taq DNA polymerase (containing no primers)

1 – 7 μl of purified PCR fragments

Add ddH2O to 10 μl

Taq mix system:

2 × Taq Master Mix                                             5 μl

Purified PCR fragments                                  1 – 7 μl

ddH2O                                                             10 μl

Reaction conditions: 72°C 10 min.